Low-tension Continuity
|
Rotate the armature until the contact-breaker
points are open.
|
|
|
Measure the resistance with the two probes of
your multi-meter shorted together. The reading will probably be a fraction of an
ohm.
|
|
|
Then measure the resistance between the two
points of the contact-breaker.
|
|
|
The reading should be between 0.5 and 0.7 ohms
greater than your first reading.
|
|
-
If it is significantly higher, there is a bad
connection or break in the low-tension circuit, in which case the magneto
will need a more complete overhaul.
-
If it is significantly lower, then there is
probably a short-circuit in the contact-breaker assembly or in the armature.
So, re-check everything in the contact-breaker assembly first before
deciding on a more complete overhaul.
|
|
Back Next
|